1st https://www.mekster.se/oljefilter-379566.html
Thumbnail(Server Power: OFF)
Server Health Summary
Inventory
Product Name Serial Number Product ID iLO Firmware Systen ROM Backup ROM iLO CPLD System CPLD iLO IPv4 iLO IPU6 iLO HostNane iLO Service Port
ProLiant ML350 Gen10 C2J819050Q 877621-421 2.96 Aug 1? 2023 U41 0?/20/2023 U41 02/09/2023 Ox10 0x10 192.168.1.10 [fe80: :eeeb:b8ff:fe94:baf2] ILOCZJ819050Q 169.254.1.2/255.255.0.0
(Press UID LED Button to return to server screen)
Critical Log Entries
[C] 05/15/2024 05:20 Slot=0 Storage - Drive at Port 2I Box 2 Bay 2 is Renoved [C]
05/15/2024 03:05 Slot=0 Storage - Drive at Port 2I Box 2 Bay 1 is Renoved [C]
05/14/2024 16:36 Server Critical Fault (Service Information: Input Power Loss, Power Supply. Power Supply 1 (03h)) [C]
05/14/2024 16:36 Server Critical Fault (Service Information: Input Power Loss, Power Supply Power Supply 1 (03h) Power Supply 2 (03h)) [C] CLOCK NOT SET Server Critical Fault (Service Information: Power On Fault, Systen Board, P12V Main/AUX Regulators (02h)) [C]
CLOCK NOT SET Server Critical Fault (Service Informat ion: Standby Fault, Systen Board, P12U Main/AUX Regulators (02h)) [C]
CLOCK NOT SET Server Critical Fault (Service Information: Power On Fault, System Board,
LG